What is fluorescence activated cell sorting

By Maukree | 12.03.2021

what is fluorescence activated cell sorting

Fluorescence-activated Cell Sorting (FACS)

Fluorescence activated cell sorting (FACS) of live cells separates a population of cells into sub-populations based on fluorescent labeling. Sorting involves more complex mechanisms in the flow cytometer than a non-sorting analysis. Cells stained using fluorophore-conjugated antibodies can be separated from one another depending on which. Flow cytometry (FC) is a technique used to detect and measure physical and chemical characteristics of a population of cells or particles.. In this process, a sample containing cells or particles is suspended in a fluid and injected into the flow cytometer instrument. The sample is focused to ideally flow one cell at a time through a laser beam, where the light scattered is characteristic to.

Flow cytometry FC is a technique used to detect and measure physical and chemical characteristics of a population of cells or particles. In this process, a sample containing cells or particles is suspended in a fluid and injected into the flow cytometer instrument. The sample is focused to ideally flow one cell at a time through a laser beam, where the light scattered is characteristic to the cells and their components. Cells are often labeled with fluorescent markers so light is absorbed and then emitted in a band of wavelengths.

Tens of thousands of cells can be quickly examined and the data gathered are processed by a computer. Flow cytometry is routinely used in basic research, clinical practice, and clinical trials. Uses for flow cytometry include:. A flow cytometry analyzer is an instrument that provides quantifiable data from a sample. Other instruments using flow cytometry include cell sorters which physically separate and thereby purify cells of interest based on their optical properties.

The first impedance -based flow cytometry device, using the Coulter principlewas disclosed in U. Patent 2,, issued into Wallace H. Mack Fulwyler was the inventor of the forerunner to today's flow cytometers - particularly the cell sorter. At that time, absorption methods were still widely favored by other scientists over fluorescence methods. The first label-free high-frequency impedance flow cytometer based on a patented microfluidic "lab-on-chip", Ampha Z30, was introduced by Amphasys The original name of the fluorescence-based flow cytometry technology was "pulse cytophotometry" German : Impulszytophotometriebased on the first patent application on fluorescence-based flow cytometry.

At the 5th American Engineering Foundation Conference on Automated Cytology in Pensacola Florida in - eight years after the introduction of the first fluorescence-based flow cytometer - it was agreed to commonly use the name "flow cytometry", a term that quickly became popular. Modern flow cytometers are able to analyze many thousands of particles per second, in "real time" and, if configured as cell sorters, can actively separate and isolate particles with specified optical properties at similar rates.

A flow cytometer is similar to a microscopeexcept that, instead of producing an image of the cell, flow cytometry offers high-throughput, automated quantification of specified optical parameters on a cell-by-cell basis. To analyze solid tissuesa single-cell suspension must first be prepared.

A flow cytometer has five main components: a flow cell, a measuring system, a detector, an amplification system, and a computer for analysis of the signals. The flow cell has a liquid stream sheath fluidwhich carries and aligns the cells so that they pass single file through the light beam for sensing.

The measuring system commonly uses measurement of impedance or conductivity and optical systems - lamps mercuryxenon ; high-power water-cooled lasers argonkryptondye laser ; low-power air-cooled lasers argon nmred-HeNe nmgreen-HeNe, HeCd UV ; diode lasers blue, green, red, violet resulting in light signals.

The detector and analog-to-digital conversion ADC system converts analog measurements of forward-scattered light FSC and side-scattered light SSC as well as dye-specific fluorescence signals into digital signals that can be processed by a computer.

The amplification system can be linear or logarithmic. The process of collecting data from samples using the flow cytometer is termed 'acquisition'. Acquisition is mediated by a computer physically connected to the flow cytometer, and the software which handles the digital interface with the cytometer. The software is capable of adjusting parameters e. What is fluorescence activated cell sorting flow cytometers were, in general, experimental devices, but technological advances have enabled widespread applications for use in a variety of both clinical and research purposes.

Due to these developments, a considerable market for instrumentation, analysis software, as well as the reagents used in acquisition such as fluorescently labeled antibodies have been developed. Modern instruments usually have multiple lasers and fluorescence detectors.

The current record for a commercial instrument is ten lasers [10] and 30 fluorescence detectors. Certain instruments can even take digital images of individual cells, allowing for the analysis of fluorescent signal location within or on the surface of cells. How to be a green puffle on club penguin must pass uniformly through the center of focused laser beams to accurately measure optical properties of cells in any flow cytometer.

Fluidics in a flow cytometer with cell sorting capabilities also use the stream to carry sorted cells into collection tubes or wells. For precise positioning of cells in a liquid jet, hydrodynamic focusing is used in most cytometers.

The sample core is maintained in the center of the sheath fluid. The sample input rate or how fast the cells flow through to the laser interrogation can be controlled by the pressure of the sheath fluid on the sample core. Under optimal conditions, the central fluid stream and sheath fluid do not mix.

Acoustic focusing technology is used in some flow cytometers to support hydrodynamic focusing. The pre-focused sample is then injected into the hydrodynamic core and flowed through the instrument. This may help with increasing data accuracy under high sample input rates. Light emitted from fluorophores are in a spectrum of wavelengths, so combining multiple fluorophores may cause overlap.

To add specificity, optical filters and dichroic mirrors are used to filter and move what is fluorescence activated cell sorting to the detectors such as photomultiplier what is fluorescence activated cell sorting PMTs or avalanche photodiodes APD. Most flow cytometers uses dichroic mirrors and band pass filters to select specific bands of the optical spectrum.

Spectral flow cytometry uses prisms or diffraction gratings to disperse the emitted light of a marker across a detector array. The measured spectra from single cells are subsequently unmixed by using reference spectra of all used dyes and the autofluorescence spectrum. This may allow for a wider panel design and the application of new biological markers. Imaging flow cytometry IFC captures multichannel images of cells. Each fluorochrome has a broad fluorescence spectrum.

When more than one fluorochrome is used, the overlap between fluorochromes can occur. This situation is called spectrum overlap. This situation needs to be overcome. For example, the emission spectrum for FITC and PE is that the light emitted by the fluorescein overlaps the same wavelength as it passes through the filter used for PE.

This process is called color compensation, which calculates a fluorochrome as a percentage to measure itself. Compensation is the mathematical process by which spectral overlap of multiparameter flow cytometric data is corrected. Since fluorochromes can have wide ranging spectrum, they can overlap, causing the undesirable result of confusion during the analysis of data. This overlap, known as spillover and quantified in the spillover coefficient, is usually caused by detectors for a certain fluorochrome measuring a significant peak in wavelength from a different fluorochrome.

Linear algebra is most often used to make this correction. In general, when graphs of one or more parameters are displayed, it is to show that the other parameters do not contribute to the distribution shown.

Especially when using the parameters which are more than double, this problem is more severe. Currently, no tools have been discovered to efficiently display multidimensional parameters. Compensation is very important to see the distinction between cells. The data generated by flow-cytometers can be plotted in a single dimensionto produce a histogramor in two-dimensional dot plots, or even in three dimensions.

The regions on these plots can be sequentially separated, based how many truck stops in usa fluorescence intensityby creating a series of subset extractions, termed "gates. Individual single cells are often distinguished from cell doublets or higher aggregates how to do rahu ketu pooja their "time-of-flight" denoted also as a "pulse-width" through the narrowly focused laser beam [18].

The plots are often made on logarithmic scales. Because different fluorescent dyes' emission spectra overlap, [19] [20] signals at the detectors have to be compensated electronically as well as computationally. Data accumulated using the flow cytometer can be analyzed using software.

Once the data is collected, there is no need to stay connected to the flow cytometer and analysis is most often performed on a separate computer. Recent progress on automated population identification using computational methods has offered an alternative to traditional gating strategies. Automated identification systems could potentially help findings of rare what do cad designers do hidden populations.

T-Distributed Stochastic Neighbor Embedding tSNE is an algorithm designed to perform dimensionality reduction, to allow visualization of complex multi-dimensional data in a two-dimensional "map". Fluorescence minus one FMO controls are important for data interpretation when building multi-color panels - in which a cell is stained with multiple fluorochromes simultaneously.

FMO controls provide a measure of fluorescence spillover in a given channel and allow for compensation. Cell sorting is a method to purify cell populations based on the presence or absence of specific physical characteristics.

Fulwyler by joining a Coulter volume sensor with the newly-invented ink jet printer. Flow cytometry cell sorters have a collection system unlike flow cytometry analyzers. The collection process starts when a sample is injected into a stream of sheath fluid that passes through the flow cell and laser intercepts. An electrical charging ring is placed just at the point where the stream breaks into droplets and a how to use triactol bust serum is placed on the ring based immediately prior to fluorescence intensity being measured; the opposite charge is trapped on the droplet as it breaks from the stream and the droplets are therefore charged.

The charged droplets then fall through an electrostatic deflection system that diverts droplets into containers based on their charge. In some systems, the charge is applied directly to the stream, and the droplet breaking off retains charge of the same sign as the stream.

The stream is then returned to neutral after the droplet breaks off. After collecting, these cells can be further cultured, manipulated, and studied. Flow cytometry uses the light properties scattered from cells or particles for identification or quantitative measurement of physical properties.

Labels, dyes, and stains can be used for multi-parametric analysis understand more properties about a cell. Immunophenotyping is the analysis of heterogeneous populations of cells using labeled antibodies [35] and other fluorophore containing reagents such as dyes and stains. A wide range of fluorophores can be used as labels in flow cytometry. Each fluorophore has a characteristic peak excitation and emission wavelength, and the emission spectra often overlap.

Consequently, the combination of labels which can be used depends on the wavelength of the lamp s or laser s used to excite the fluorochromes and on the detectors available. Absolute fluorescence sensitivity is generally lower in confocal microscopy because out-of-focus signals are rejected by the confocal optical system and because the image is built up serially from individual measurements at every location across the cell, reducing the amount of time available to collect signal.

Quantum dots are sometimes used in place of traditional fluorophores because of their narrower emission peaks. Mass cytometry overcomes the fluorescent labeling limit by utilizing lanthanide isotopes attached to antibodies. This method could theoretically allow the use of 40 to 60 distinguishable labels and has been demonstrated for 30 labels.

Although this method permits the use of a large number of labels, it currently has lower throughput capacity than flow cytometry. It also destroys the analysed cells, precluding their recovery by sorting. In addition to the ability to label and identify individual cells via fluorescent antibodies, cellular products such as cytokines, proteins, and other factors may be measured as well. Similar to ELISA sandwich assays, cytometric bead array CBA assays use multiple bead populations typically differentiated by size and different levels of fluorescence intensity to distinguish multiple analytes in a single assay.

The amount of the analyte captured is detected via a biotinylated antibody against a secondary epitope of the protein, followed by a streptavidin-R-phycoerythrin treatment. The fluorescent intensity of R-phycoerythrin on the beads is quantified on a flow cytometer equipped how to make a rubber band plane a nm excitation source.

Fluorescence-activated cell sorting (FACS)

Fluorescence-activated cell sorting (FACS) is a technique to purify specific cell populations based on phenotypes detected by flow cytometry. This method enables researchers to better understand. Fluorescence-activated cell sorting (FACS) is a specialized type of flow cytometry. It provides a method for sorting a heterogeneous mixture of biological cells into two or more containers, one cell at a time, based upon the specific light scattering and fluorescent characteristics of each cell. The sorting of specific cells from complex mixtures is necessary for a variety of applications, ranging from cancer research, to assisted reproduction, cell-based therapies, and the selection of genetically modified cells. Two of the primary affinity-based techniques used for cell sorting are fluorescence-activated cell sorting (FACS) and magnetic-activated cell sorting (MACS).

These metrics are regularly updated to reflect usage leading up to the last few days. Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts. The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online.

Clicking on the donut icon will load a page at altmetric. Find more information on the Altmetric Attention Score and how the score is calculated. Magnetic-activated cell sorting MACS is an affinity-based technique used to separate cells according to the presence of specific markers. Current MACS systems generally require an antigen to be expressed at the cell surface; these antigen-presenting cells subsequently interact with antibody-labeled magnetic particles, facilitating separation.

Here, we present an alternative MACS method based on coiled-coil peptide interactions. We demonstrate that HeLa, CHO, and NIH3T3 cells can either incorporate a lipid-modified coiled-coil-forming peptide into their membrane, or that the cells can be transfected with a plasmid containing a gene encoding a coiled-coil-forming peptide. Iron oxide particles are functionalized with the complementary peptide and, upon incubation with the cells, labeled cells are facilely separated from nonlabeled populations.

In addition, the resulting cells and particles can be treated with trypsin to facilitate detachment of the cells from the particles. Therefore, our new MACS method promotes efficient cell sorting of different cell lines, without the need for antigen presentation, and enables simple detachment of the magnetic particles from cells after the sorting process.

Such a system can be applied to rapidly developing, sensitive research areas, such as the separation of genetically modified cells from their unmodified counterparts. Figure 1. Coiled-coil-based MACS. Cells are either A functionalized with a coiled-coil forming peptide or B transfected with a K 3 -containing plasmid; low transfection rates mean not all cells express the K 3 peptide. IOPs bearing the complementary peptide are added and separation is facilitated by coiled-coil formation and application of a magnetic field.

Postseparation, cells are separated from the IOPs via trypsinization. Figure 2. Coiled-coil-functionalized magnetic particles. A Schematic of fluorescent labeling of the IOPs: coiled-coil functionalized IOPs are incubated with the complementary fluorescent peptide. B Tryptophan fluorescence spectrum of functionalized IOPs, indicating attachment of the peptides to the particles.

C Fluorescein fluorescence spectrum of fluorescently labeled IOPs; a fluorescein spectrum is only observed when the IOPs are labeled with the complementary peptide. Figure 3. Error is calculated as the standard deviation from the average of at least two independent measurements.

Figure 4. HeLa cell membrane labeling and cell sorting. The transfected cells were subsequently incubated with Cy5-E 3 to demonstrate successful expression of K 3 at the cell surface. Green channel, GFP; red channel, Cy5.

Green channel: GFP. Figure 5. All images are an overlay of bright-field and fluorescence microscopy images. Errors are calculated as the standard deviation from the average of at least two independent measurements. Such files may be downloaded by article for research use if there is a public use license linked to the relevant article, that license may permit other uses. All authors contributed to the experimental design.

All authors analyzed the data. The manuscript was written by M. Interfaces , 13 , 10 , More by Meng-Jie Shen. More by Ye Zeng. More by Thomas Bakkum. More by Alexander Kros. More by Aimee L. Cite this: ACS Appl. Interfaces , 13 , 10 , — Published by American Chemical Society.

Article Views Altmetric -. Abstract High Resolution Image. MACS can circumvent these disadvantages: no specialist equipment is required and no fluorescent labels are needed. Instead, MACS employs magnetic particles that can be functionalized to enable binding to a subset of cells in a mixture, facilitating separation.

The beads and the cells are incubated and subsequently placed in a magnetic field. Cells that do not express the antigen of interest are not retained in the magnetic field, whereas cells that do display the antigen of interest bind to the beads and are retained. Once the magnetic field is removed, the cells of interest can be eluted. However, MACS does have disadvantages: functionalization of the iron oxide particles IOPs with antibodies is not trivial, and such antibodies are typically expensive.

For example, magnetic particles can influence the phenotype and function of some cells, 19,20 in addition to affecting cell viability. Therefore, there is a need to design and synthesize functionalized magnetic particles that possess a high specificity for the cells of interest and are facile to dissociate from the cells after separation. Such a system would benefit multiple areas of cell biology and medicine, for example facilitating the separation, and subsequent enrichment, of genetically modified cells.

Coiled coils are a protein-folding motif comprising two or more alpha-helices that interact to form a left-handed supercoil. Therefore, we designed a MACS system based on interactions between magnetic beads and cells that were functionalized with complementary coiled-coil forming peptides Figure 1. Subsequent application of an external magnetic field facilitated isolation of these cells with high efficiency and specificity Figure 1 A. Another advantage of this system is that the coiled-coil peptides could be degraded by trypsin, which made the dissociation of the cells from the IOPs facile and efficient.

These cells express K 3 on their membrane and we show that these cells could be separated Figure 1 B , and subsequently enriched, from nontransfected cells.

These results demonstrate that our coiled-coil based MACS system can facilitate cell separation, and subsequent enrichment of transfected cells, with high specificity and efficiency. High Resolution Image. Results and Discussion. Functionalized magnetic particles suitable for cell sorting need to possess several properties including specificity for the cells of interest, high binding and separation efficiency, and effective dissociation.

To fulfill these criteria, we designed a coiled-coil-functionalized IOP system. This tight binding enables peptide-functionalized IOPs to bind to the complementary peptide with high efficiency Figure 2 A. IOPs need to be coated to reduce nonspecific interactions with cells and to facilitate functionalization with a moiety specific to the cells of interest.

An added advantage is that the number of DVS groups can be adjusted by synthesizing Dex-DVS with differing degrees of substitution, allowing for control over the number of functional groups displayed on the surface of the IOPs.

Conjugation of the coiled-coil forming peptides to the IOPs was facilitated by modifying the peptides to include a free sulfhydryl group. These peptides incorporate a cysteine Cys, C at their C-terminus.

A polyethylene glycol PEG spacer was included between the cysteine and the rest of the peptide sequence to minimize potential steric hindrance, which may impact coiled-coil formation. A tryptophan Trp, W was included to facilitate detection and quantification of the peptide. To demonstrate the peptide-functionalized IOPs were successfully synthesized, we employed fluorescence spectroscopy. IOPs functionalized with the coiled-coil forming peptides exhibit a fluorescence spectrum corresponding to that of Trp Figure 2 B , which indicates the peptides were successfully conjugated to the IOPs.

Coiled-coil formation was subsequently confirmed using a fluorescence labeling assay. Figure 2 C shows that a fluorescein fluorescence spectrum is only observed when the peptides are mixed with IOPs functionalized with the complementary peptides. This indicates coiled-coil formation and demonstrates that no nonspecific binding between fluo-E 3 or fluo-K 3 and nonfunctionalized IOPs occurs.

The results were verified by confocal microscopy imaging Figure 2 D—G. The unmodified IOPs did not exhibit fluorescence after incubation with fluo-K 3 or fluo-E 3 Figure 2 D, F , whereas peptide-modified IOPs have a green fluorescent surface after labeling with the complementary peptide, i. This anchor enables the insertion of the lipopeptide into the lipid bilayer of a cell membrane. By functionalizing specific cells with these lipopeptides and adding IOPs functionalized with the complementary coiled-coil forming peptide, cells can be separated from others in a mixture.

To confirm that the lipopeptides synthesized for this study are capable of inserting into the cell membrane and subsequently forming a coiled coil, we performed a cell membrane labeling assay. The fluo-K 3 or fluo-E 3 peptides were added to cells decorated with the complementary lipopeptide. Using confocal microscopy, it was determined that the lipopeptide-decorated cells exhibited a fluorescently labeled membrane, whereas no fluorescent labeling was observed on nondecorated cell membranes Figure S1.

After it was confirmed that coiled-coil forming peptides could be used to functionalize IOPs and cell membranes and that coiled-coil formation occurred, a proof-of-principle coiled-coil-mediated MACS experiment was designed.

Green cells were incubated with CPK 3 for 1 h, before being mixed with the same number of red cells. IOP-E 3 were subsequently added to the cell mixture. Through the application of an external magnetic field, cells attached to the magnetic particles could be isolated.

The IOP-attached cells could subsequently be treated with trypsin to dissociate the magnetic particles before an external magnetic field could again be used to separate the IOPs from the detached HeLa cells. To demonstrate that the cells can be cleaved from the IOPs, we incubated them with trypsin and then separated from the IOPs using an external magnetic field. Figure 3 D shows the image of the cells after dissociation: most of the cells exhibit green fluorescence.

After MACS, the cells were allowed to grow for 24 h before imaging again to demonstrate that both the cells from the supernatant Figure 3 F and the cells detached from the IOPs Figure 3 G remain viable. Although confocal imaging provides a qualitative impression of the efficiency of this system, quantification of cell separation is desirable. Therefore, flow cytometry was employed for all three cell lines.

Before MACS, the flow cytometry data shows the cells are mixed in an approximately ratio, as designed, Table 1.